Please use this identifier to cite or link to this item: http://repositorio.ufla.br/jspui/handle/1/50086
Title: Evaluation of high rate ponds operational and design strategies for algal biomass production and domestic wastewater treatment
Keywords: Open algae ponds
CO2 supplementation
UV pre-disinfection
Domestic sewage
Algal biomass
Lagos abertos de algas
Suplementação de CO2
Pré-desinfecção UV
Esgoto doméstico
Esgoto doméstico
Issue Date: 15-Oct-2021
Publisher: Elsevier
Citation: COUTO, E. et al. Evaluation of high rate ponds operational and design strategies for algal biomass production and domestic wastewater treatment. Science of The Total Environment, Amsterdam, v. 791, 148362, 15 Oct. 2021. DOI: 10.1016/j.scitotenv.2021.148362.
Abstract: This study evaluated the effect of high rate ponds (HRPs) depth on algal biomass production during domestic wastewater treatment. HRPs were evaluated for 20, 30, and 40 cm depths, with and without CO2 supplementation. In addition, 40 cm deep HRP with ultraviolet (UV) pre-disinfection was evaluated. The concentration of chlorophyll-a as a function of time for each evaluated condition was represented by logistic models that were after submitted to cluster analysis. The 20 cm HRPs presented higher chlorophyll-a concentration, reaching a maximum of 5.8 and 4.3 mg L−1, in the HRPs with and without CO2 addition, respectively. Ammonia nitrogen and soluble phosphorus were greater removed in shallower HRPs. The addition of CO2 influenced the nutrient removal processes, optimizing nutrient recovery by biomass assimilation. HRP configuration did not influence organic matter removal (~40% of removal efficiency in all HRPs), predominant microalgae genera (Chlorella sp. and Scenedesmus), and E. coli inactivation (removal of ~2 log units), except for the 20 cm HRP without CO2 that had removal of 4 log units due to high pH values. For HRPs with CO2 addition and UV pre-disinfection, the models for 40 cm were grouped together with those obtained for 30 cm HRPs, indicating the same behavior for chlorophyll-a production as a function of time. Thus, it can be concluded that the evaluated strategies represent alternatives for reducing HRP area requirements. Moreover, results may represent advancement and major contributions for HRP design criteria.
URI: https://doi.org/10.1016/j.scitotenv.2021.148362
http://repositorio.ufla.br/jspui/handle/1/50086
Appears in Collections:DRH - Artigos publicados em periódicos

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.