Title: | Efeitos da fertirrigação sobre corrosão em aço galvanizado utilizado em pivô central |
Other Titles: | Effects of fertirrigation on corrosion of galvanized steel used in center pivot |
Authors: | Lima, Luiz Antonio Thebaldi, Michael Silveira Lima, Luiz Antonio Thebaldi, Michael Silveira Lauro, Carlos Henrique |
Keywords: | Taxa de corrosão Perda de massa Teste de imersão Fertirrigação Corrosion rate Mass loss Immersion test Fertigation |
Issue Date: | 16-Apr-2019 |
Publisher: | Universidade Federal de Lavras |
Citation: | RODRIGUES, K. V. Efeitos da fertirrigação sobre corrosão em aço galvanizado utilizado em pivô central. 2019. 56 p. Dissertação (Mestrado em Recursos Hídricos)-Universidade Federal de Lavras, Lavras, 2019. |
Abstract: | One of the main causes of deterioration and reduction of the lifetime of agricultural equipment is corrosion. In central pivot irrigation systems, corrosion occurs mainly in galvanized steel pipes, causing problems such as reduction of water application efficiency, contamination of irrigation water, leaks and reduction of equipment lifetime. The center pivot is one of the most widely used irrigation systems because it has advantages such as the use of fertigation, which can increase corrosion, once fertilizers in contact with water or moisture become corrosive. This research evaluated the corrosion caused by fertigation in galvanized steel test specimens similar to those used in center pivots, simulating 10 years of fertigation with frequency of 5 times a year and duration of 7 hours, by means of immersion tests in solutions containing 0, 5 and 10 g/l of the fertilizer 20-00-20, in order to obtain the mass loss per area of metallic material, annual average penetration rate in steel and the effect of fertigation on the lifetime of center pivot. The mass loss per area increased with the time of exposure in the corrosive environment and with the fertilizing concentration, the average corrosion rate decreased with the exposure time and there was a slight reduction in the estimated useful life of the zinc coating layer exposed to fertilizer 20-00-20. The results obtained showed that fertigation increased corrosion in galvanized steel used in center pivot pipes. |
URI: | http://repositorio.ufla.br/jspui/handle/1/33638 |
Appears in Collections: | Recursos Hídricos - Mestrado (Dissertações) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
DISSERTAÇÃO_Efeitos da fertirrigação sobre corrosão em aço galvanizado utilizado em pivô central.pdf | 1,41 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.