Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/42512
Registro completo de metadados
Campo DCValorIdioma
dc.creatorKohmer, Niko-
dc.creatorWesthaus, Sandra-
dc.creatorRühl, Cornelia-
dc.creatorCiesek, Sandra-
dc.creatorRabenau, Holger F.-
dc.date.accessioned2020-08-20T19:18:04Z-
dc.date.available2020-08-20T19:18:04Z-
dc.date.issued2020-08-
dc.identifier.citationKOHMER, N. et al. Brief clinical evaluation of six high-throughput SARS-CoV-2 IgG antibody assays. Journal of Clinical Virology, [S.l.], v. 129, Aug. 2020.pt_BR
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S1386653220302225pt_BR
dc.identifier.urihttp://repositorio.ufla.br/jspui/handle/1/42512-
dc.description.abstractSerological SARS-CoV-2 assays are urgently needed for diagnosis, contact tracing and for epidemiological studies. So far, there is limited data on how recently commercially available, high-throughput immunoassays, using different recombinant SARS-CoV-2 antigens, perform with clinical samples. Focusing on IgG and total antibodies, we demonstrate the performance of four automated immunoassays (Abbott Architect™ i2000 (N protein-based)), Roche cobas™ e 411 analyzer (N protein-based, not differentiating between IgA, IgM or IgG antibodies), LIAISON®XL platform (S1 and S2 protein-based), VIRCLIA® automation system (S1 and N protein-based) in comparison to two ELISA assays (Euroimmun SARS-CoV-2 IgG (S1 protein-based) and Virotech SARS-CoV-2 IgG ELISA (N protein-based)) and an in-house developed plaque reduction neutralization test (PRNT). We tested follow up serum/plasma samples of individuals PCR-diagnosed with COVID-19. When calculating the overall sensitivity, in a time frame of 49 days after first PCR-positivity, the PRNT as gold standard, showed the highest sensitivity with 93.3% followed by the dual-target assay for the VIRCLIA® automation system with 89%. The overall sensitivity in the group of N protein-based assays ranged from 66.7 to 77.8% and in the S protein-based-assays from 71.1 to 75.6%. Five follow-up samples of three individuals were only detected in either an S and/or N protein-based assay, indicating an individual different immune response to SARS-CoV-2 and the influence of the used assay in the detection of IgG antibodies. This should be further analysed. The specificity of the examined assays was ≥ 97%. However, because of the low or unknown prevalence of SARS-CoV-2, the examined assays in this study are currently primarily eligible for epidemiological investigations, as they have limited information in individual testing.pt_BR
dc.languageen_USpt_BR
dc.publisherElsevierpt_BR
dc.rightsrestrictAccesspt_BR
dc.sourceJournal of Clinical Virologypt_BR
dc.subjectSevere Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2)pt_BR
dc.subjectImmunoglobulin G (IgG)pt_BR
dc.subjectAssaypt_BR
dc.subjectEvaluationpt_BR
dc.subjectPlaque reduction neutralization test (PRNT)pt_BR
dc.titleBrief clinical evaluation of six high-throughput SARS-CoV-2 IgG antibody assayspt_BR
dc.typeArtigopt_BR
Aparece nas coleções:FCS - Artigos sobre Coronavirus Disease 2019 (COVID-19)

Arquivos associados a este item:
Não existem arquivos associados a este item.