Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/37833
Registro completo de metadados
Campo DCValorIdioma
dc.creatorRibeiro-Soares, J.-
dc.creatorOliveros, M. E.-
dc.creatorGarin, C.-
dc.creatorDavid, M. V.-
dc.creatorMartins, L. G. P.-
dc.creatorAlmeida, C. A.-
dc.creatorMartins-Ferreira, E. H.-
dc.creatorTakai, K.-
dc.creatorEnoki, T.-
dc.creatorMagalhães-Paniago, R.-
dc.creatorMalachias, A.-
dc.creatorJorio, A.-
dc.creatorArchanjo, B. S.-
dc.creatorAchete, C. A.-
dc.creatorCançado, L. G.-
dc.date.accessioned2019-11-28T16:54:04Z-
dc.date.available2019-11-28T16:54:04Z-
dc.date.issued2015-12-
dc.identifier.citationRIBEIRO-SOARES, J. et al. Structural analysis of polycrystalline graphene systems by Raman spectroscopy. Carbon, Elmsford, v. 95, p. 646-652, Dec. 2015.pt_BR
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0008622315301391#!pt_BR
dc.identifier.urihttp://repositorio.ufla.br/jspui/handle/1/37833-
dc.description.abstractA theoretical model supported by experimental results explains the dependence of the Raman scattering signal on the evolution of structural parameters along the amorphization trajectory of polycrystalline graphene systems. Four parameters rule the scattering efficiencies, two structural and two related to the scattering dynamics. With the crystallite sizes previously defined from X-ray diffraction and microscopy experiments, the three other parameters (the average grain boundaries width, the phonon coherence length, and the electron coherence length) are extracted from the Raman data with the geometrical model proposed here. The broadly used intensity ratio between the C–C stretching (G band) and the defect-induced (D band) modes should be used to measure samples with crystallite sizes larger than the phonon coherence length, which is found equal to 32 nm. The Raman linewidth of the G band is more appropriate to characterize the crystallite sizes below the phonon coherence length, down to the average grain boundaries width, which is found to be 2.8 nm. “Ready-to-use” equations to determine the crystallite dimensions based on the Raman spectroscopy data are given.pt_BR
dc.languageen_USpt_BR
dc.publisherElsevierpt_BR
dc.rightsrestrictAccesspt_BR
dc.sourceCarbonpt_BR
dc.subjectRaman spectroscopypt_BR
dc.subjectGraphenept_BR
dc.subjectCrystallite sizept_BR
dc.subjectPolycrystallinept_BR
dc.subjectEspectroscopia Ramanpt_BR
dc.subjectGrafenopt_BR
dc.subjectTamanho de cristalitapt_BR
dc.subjectPolicristalinopt_BR
dc.titleStructural analysis of polycrystalline graphene systems by Raman spectroscopypt_BR
dc.typeArtigopt_BR
Aparece nas coleções:DFI - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.