Use este identificador para citar ou linkar para este item:
http://repositorio.ufla.br/jspui/handle/1/36660
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Teixeira, Meryene de C. | - |
dc.creator | Felix, Fabiana S. | - |
dc.creator | Thomasi, Sérgio S. | - |
dc.creator | Magriotis, Zuy M. | - |
dc.creator | Silva, Josiane M. da | - |
dc.creator | Okumura, Leonardo L. | - |
dc.creator | Saczk, Adelir A. | - |
dc.date.accessioned | 2019-09-05T19:16:25Z | - |
dc.date.available | 2019-09-05T19:16:25Z | - |
dc.date.issued | 2019-07 | - |
dc.identifier.citation | TEIXEIRA, M. de C. et al. Voltammetric determination of organic nitrogen compounds in environmental samples using carbon paste electrode modified with activated carbon. Microchemical Journal, New York, v. 148, p. 66-72, July 2019. | pt_BR |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0026265X18316394 | pt_BR |
dc.identifier.uri | http://repositorio.ufla.br/jspui/handle/1/36660 | - |
dc.description.abstract | A quick and simple procedure is described to determine pyridine and quinoline using voltammetric methods and carbon paste electrodes modified with activated carbon in the proportion of 50:20:30 w/w graphite:activated carbon:silicon. Studies with cyclic voltammetry indicated that reduction of organic nitrogen molecules is irreversible in ammonium chloride solution acidified to pH 2.5 with Britton-Robinson buffer. Under the best optimum conditions for the differential pulse voltammetry for pyridine and square wave voltammetry for quinoline, the analytical curve was linear from 1.0 × 10−4 to 9.0 × 10−7 mol L−1 for both analytes with limits of detection of approximately 2.0 × 10−7 mol L−1 and limits of quantification of approximately 7.0 × 10−7 mol L−1. The proposed methods were successfully applied to determine pyridine and quinoline in samples of textile effluents and fuel with minimum sample treatment. | pt_BR |
dc.language | en_US | pt_BR |
dc.publisher | Elsevier | pt_BR |
dc.rights | restrictAccess | pt_BR |
dc.source | Microchemical Journal | pt_BR |
dc.subject | Organic nitrogen compounds - Voltammetric determination | pt_BR |
dc.subject | Pyridine | pt_BR |
dc.subject | Quinoline | pt_BR |
dc.subject | Square-wave voltammetry | pt_BR |
dc.subject | Textile effluents | pt_BR |
dc.subject | Compostos nitrogenados orgânicos - Determinação voltamétrica | pt_BR |
dc.subject | Piridina | pt_BR |
dc.subject | Quinolina | pt_BR |
dc.subject | Voltametria de onda quadrada | pt_BR |
dc.subject | Efluentes têxteis | pt_BR |
dc.title | Voltammetric determination of organic nitrogen compounds in environmental samples using carbon paste electrode modified with activated carbon | pt_BR |
dc.type | Artigo | pt_BR |
Aparece nas coleções: | DEG - Artigos publicados em periódicos DQI - Artigos publicados em periódicos |
Arquivos associados a este item:
Não existem arquivos associados a este item.
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.