Use este identificador para citar ou linkar para este item:
http://repositorio.ufla.br/jspui/handle/1/32511
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Lourenção, Bruna C. | - |
dc.creator | Medeiros, Roberta A. | - |
dc.creator | Thomasi, Sérgio Scherrer | - |
dc.creator | Ferreira, Antonio Gilberto | - |
dc.creator | Rocha-Filho, Romeu C. | - |
dc.creator | Fatibello-Filho, Orlando | - |
dc.date.accessioned | 2019-01-25T09:21:33Z | - |
dc.date.available | 2019-01-25T09:21:33Z | - |
dc.date.issued | 2016-01 | - |
dc.identifier.citation | LOURENCAO, B. C. et al. Amperometric flow-injection determination of the anthelmintic drugs ivermectin and levamisole using electrochemically pretreated boron-doped diamond electrodes. Sensors and Actuators B: Chemical, Lausanne, v. 222, p. 181-189, Jan. 2016. | pt_BR |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0925400515302148#! | pt_BR |
dc.identifier.uri | http://repositorio.ufla.br/jspui/handle/1/32511 | - |
dc.description.abstract | Sensitive, simple, low-cost, and rapid amperometric flow-injection methods were developed for determination of ivermectin (IVM) and levamisole (LVM) in anthelmintic pharmaceutical drugs and urine samples. These determinations were carried out with a cathodically (for IVM) or anodically (for LVM) pretreated boron-doped diamond electrode using aqueous 0.5 mol L−1 H2SO4 (with and without addition of 30% V/V of ethanol) as supporting electrolyte. The amperometric detection was performed at an applied electrode potential of E = 1.40 V, for IVM, and E = 1.90 V, for LVM, vs. Ag/AgCl (3.0 mol L−1 KCl). The respective analytical curves presented good linearity in the investigated concentration ranges (0.60–50 μmol L−1, for IVM, and 0.010–5.0 μmol L−1, for LVM) and the detection limits were 0.30 μmol L−1 for IVM, and 1 nmol L−1, for LVM. Investigation of possible interferents showed no significant interference with the here-proposed methods; thus, they were used to determine IVM and LVM in pharmaceutical formulations as well as in urine samples, with results that showed good agreement with comparative methods. Furthermore, a mechanism for LVM electrooxidation was proposed using exhaustive potentiostatic electrolysis and NMR measurements. | pt_BR |
dc.language | en_US | pt_BR |
dc.publisher | Elsevier | pt_BR |
dc.rights | restrictAccess | pt_BR |
dc.source | Sensors and Actuators B: Chemical | pt_BR |
dc.subject | Ivermectin | pt_BR |
dc.subject | Levamisole | pt_BR |
dc.subject | Amperometric detection | pt_BR |
dc.subject | Electrochemical pretreatment | pt_BR |
dc.subject | Ivermectina | pt_BR |
dc.subject | Detecção amperométrica | pt_BR |
dc.subject | Pré-tratamento eletroquímico | pt_BR |
dc.title | Amperometric flow-injection determination of the anthelmintic drugs ivermectin and levamisole using electrochemically pretreated boron-doped diamond electrodes | pt_BR |
dc.type | Artigo | pt_BR |
Aparece nas coleções: | DQI - Artigos publicados em periódicos |
Arquivos associados a este item:
Não existem arquivos associados a este item.
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.