Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/57193
Registro completo de metadados
Campo DCValorIdioma
dc.creatorMesquita, Luciane dos Reis-
dc.creatorMuzzi, Leonardo Augusto Lopes-
dc.creatorGiannico, Amália Turner-
dc.creatorMuzzi, Ruthnéa Aparecida Lázaro-
dc.creatorMonteiro, Juliana Fonseca-
dc.creatorBrienza, Paula Desjardins-
dc.date.accessioned2019-01-25T15:09:47Z-
dc.date.accessioned2023-06-27T18:25:02Z-
dc.date.available2019-01-25T15:09:47Z-
dc.date.available2023-06-27T18:25:02Z-
dc.date.issued2016-
dc.identifier.citationMESQUITA, L. dos R. et al. Proximal tibial epiphysiodesis in a growing dog. Acta Scientiae Veterinariae, Porto Alegre, v. 44, p. 1-4, 2016.pt_BR
dc.identifier.urihttp://www.ufrgs.br/actavet/44-suple-1/CR_113.pdfpt_BR
dc.identifier.urihttp://repositorio.ufla.br/jspui/handle/1/57193-
dc.description.abstractThe aim of this communication was to evaluate the effectiveness of the locking screw and cauterizing the growth plate of the tibial plateau as a preventive method of cranial cruciate ligament rupture. One stifle joint of a young dog was randomly chosen for placing a screw in order to block the tibial plateau growth line. A 3.5 mm × 20 mm cancellous bone screw in the dorsocranial surface of the tibial plateau of the left hindlimb. Two months after the first surgical intervention, the contralateral limb was cauterized in the tibial plateau growth line. Electrocauterization was performed with a spatula electrode set at 60 watts, performing ablation on the cranial third of the tibial plateau physis with access to the medial and lateral surfaces of the proximal tibia. The electrode was placed against the physis for 10 seconds at each site. Both members were followed radiographically to measure the tibial plateau angle and observed the angle reduction. After 30 and 60 days post-surgery, the tibial plateau angle in left hindlimb decreased to 11° and -4°, respectively. However, the decreased tibial plateau angle was tight and the screw was removed from the bone. However, even with the proximal tibial physis still open, withdrawing the screw did not alter the tibial plateau angle, which remained at -4° until the animal reached adulthood. The right left hindlimb was used as a control until the dog was 6 months old, and the tibial plateau angle exhibited a 26° angle. The electrocauterization technique of the tibial plateau angle decreased to 18° and 16° at 30 and 60 days after surgery, respectively, and remained at this last value until the animal completed its growth.pt_BR
dc.languageen_USpt_BR
dc.publisherUniversidade Federal do Rio Grande do Sulpt_BR
dc.rightsrestrictAccesspt_BR
dc.sourceActa Scientiae Veterinariaept_BR
dc.subjectCranial cruciate ligamentpt_BR
dc.subjectLocking screwpt_BR
dc.subjectElectrocauterizationpt_BR
dc.subjectStifle jointpt_BR
dc.subjectLigamento cruzado cranialpt_BR
dc.subjectParafuso bloqueantept_BR
dc.subjectEletrocauterizaçãopt_BR
dc.subjectArticulação fêmoro-tíbio-patelarpt_BR
dc.titleProximal tibial epiphysiodesis in a growing dogpt_BR
dc.title.alternativeEpifisiodese tibial proximal em um cão em crescimentopt_BR
dc.typeArtigopt_BR
Aparece nas coleções:DMV - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.