Use este identificador para citar ou linkar para este item:
http://repositorio.ufla.br/jspui/handle/1/42271
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Bazzana, Matheus Julien Ferreira | - |
dc.creator | Saczk, Adelir Aparecida | - |
dc.creator | Faria, Letícia Rodrigues | - |
dc.creator | Campos, João Pedro | - |
dc.creator | Alves, Nadja Gomes | - |
dc.creator | Borges, Cleber Nogueira | - |
dc.date.accessioned | 2020-08-06T17:49:09Z | - |
dc.date.available | 2020-08-06T17:49:09Z | - |
dc.date.issued | 2020 | - |
dc.identifier.citation | BAZZANA, M. J. F. et al. Moore-Penrose generalized inverse mixture design applied in low‐density dispersive liquid–liquid microextraction. Journal of Chemometrics, [S.l.], 2020. | pt_BR |
dc.identifier.uri | https://onlinelibrary.wiley.com/doi/abs/10.1002/cem.3275 | pt_BR |
dc.identifier.uri | http://repositorio.ufla.br/jspui/handle/1/42271 | - |
dc.description.abstract | The modification in the nutritional composition of the ruminant diet causes significant alterations in the fatty acids (FAs) structure supplemented because of the action of rumen microorganisms. The modification in the FAs structure alters the role that these play in the ruminant metabolism. The Folch method is the most often used to determine fatty acids in these animals' tissues and presents certain disadvantages such as the great volume of solvent and low mass transfer from the analyte to the extracting phase. Thus, we tested the low‐density dispersive liquid–liquid microextraction (LD‐DLLME) as an alternative method to determine these substances. In this paper, a simples‐augmented mixture design was used. The Scheffé's polynomial was applied in that design, and Moore–Penrose generalized matrix inverse was used because of the possibility of concurrently determining value estimates of coefficients of the parameters that represent cubic terms. The application of the modeling allowed the chemical interpretation of the LD‐DLLME best extraction condition for linoleic acid in ruminant serum samples. | pt_BR |
dc.language | en_US | pt_BR |
dc.publisher | Wiley | pt_BR |
dc.rights | restrictAccess | pt_BR |
dc.source | Journal of Chemometrics | pt_BR |
dc.subject | Blood serum | pt_BR |
dc.subject | Linoleic acid | pt_BR |
dc.subject | Miniaturized technique | pt_BR |
dc.subject | Mixture design | pt_BR |
dc.subject | Ruminants | pt_BR |
dc.title | Moore-Penrose generalized inverse mixture design applied in low‐density dispersive liquid–liquid microextraction | pt_BR |
dc.type | Artigo | pt_BR |
Aparece nas coleções: | DQI - Artigos publicados em periódicos |
Arquivos associados a este item:
Não existem arquivos associados a este item.
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.