Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/41030
Registro completo de metadados
Campo DCValorIdioma
dc.creatorPaula, Daniella Aparecida-
dc.creatorMurgas, Luis David Solis-
dc.creatorCastro, Tássia Flávia Dias-
dc.creatorAssis, Isadora-
dc.creatorReis Neto, Rafael Vilhena-
dc.creatorMarcussi, Silvana-
dc.date.accessioned2020-05-18T16:36:02Z-
dc.date.available2020-05-18T16:36:02Z-
dc.date.issued2019-07-
dc.identifier.citationPAULA, D. A. et al. Effects of cooling rates on the quality of Prochilodus lineatus (Valenciennes, 1836) sperm. Reproduction in Domestic Animals, [S.l.], v. 54, n. 7, July 2019.pt_BR
dc.identifier.urihttps://onlinelibrary.wiley.com/doi/10.1111/rda.13459pt_BR
dc.identifier.urihttp://repositorio.ufla.br/jspui/handle/1/41030-
dc.description.abstractThis study aims to investigate the effect of different cooling rates on the semen cryopreservation of curimba (Prochilodus lineatus). Nineteen ejaculates were obtained from adults males and cryopreserved at 15°C/min (CR15), 30°C/min (CR30) (controlled temperature inside and outside straw, speed was stable during freezing) and direct freezing in liquid nitrogen vapour (~35.6°C/min) (CRNV). The straws were thawed and seminal parameters evaluated. DNA fragmentation through the comet assay was assessed. A fresh sperm sample was not frozen and used for analyses. Data were submitted to an analysis of variance (ANOVA), and means were compared by Scott–Knott test (p < 0.05) using the R Software. Mean motility percentage was 100%, and motility duration was 39.5 ± 5.7 s for the fresh sperm (subjective analysis); 58.9 ± 8.0% and 24.5 ± 5.7 s for CR15; 64.8 ± 4.8% and 26.5 ± 7.1 s for CR30; and 50.1 ± 16% and 25.7 ± 4.7 s for CRNV, respectively. Motility percentages were higher and equal between CR15 and CR30 compared to CRNV (p < 0.05). Some sperm motion kinetics, namely average path velocity (VAP) and straight line velocity (VAS), were higher for CR30 (p < 0.05), while curvilinear velocity (VCL) and velocity progression (PRO) were lower for CRNV (p < 0.05). Straightness (STR) and wobble (WOB) were the same among treatments (p > 0.05). Sperm morphology results indicated higher means for total morphological sperm alterations in CRNV. All cooling rates caused sperm DNA fragmentation, although CR30 provided a less harmful effect. This is the first report for cryopreserved P. lineatus sperm preserved under different controlled cooling rates. The cooling rate of 30°C/min is indicated for the cryopreservation of this fish sperm as it led to the lowest detrimental spermatozoa effects.pt_BR
dc.languageen_USpt_BR
dc.rightsrestrictAccesspt_BR
dc.sourceReproduction in Domestic Animalspt_BR
dc.subjectCryopreservationpt_BR
dc.subjectFreezing ratept_BR
dc.subjectNeotropical fishpt_BR
dc.subjectReproductionpt_BR
dc.titleEffects of cooling rates on the quality of Prochilodus lineatus (Valenciennes, 1836) spermpt_BR
dc.typeArtigopt_BR
Aparece nas coleções:DMV - Artigos publicados em periódicos
DQI - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.