Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/40806
Título: Elemental concentration via portable x-ray fluorescence spectrometry: assessing the impact of water content
Título(s) alternativo(s): Concentração elementar obtida por espectrometria de fluorescência de raios-x portátil: efeito da umidade
Palavras-chave: Proximal sensors
X-ray scattering
Spectroscopy analysis
Sensores proximais
Espalhamento de raios-X
Análise espectrométrica
Data do documento: Mai-2019
Editor: Universidade Federal de Lavras
Citação: SANTANA, M. L. T. et al. Elemental concentration via portable x-ray fluorescence spectrometry: assessing the impact of water contente. Ciência e Agrotecnologia, Lavras, v. 43, 2019. Paginação irregular.
Resumo: Portable X-ray fluorescence (pXRF) analysis can be considered one of the main recent advances for chemical characterization of earth materials. The water content of the samples can affect the pXRF performance. As a novelty, we aimed to establish relationships (linear regression) between the effect of water content on pXRF results and atomic number (Z) of the elements. Three certified reference materials (CRM) were investigated: OREAS 100a, OREAS 101a, and OREAS 101b. These materials were saturated (0.68 g g-1) with distilled water and left to air-dry naturally. During the drying, the elemental concentrations (C) were determined at different water contents using a pXRF spectrometer. For each water content, the ratio Cwet/Cdry was determined and plotted against the water content. The attenuation coefficient (σ) was also determined. High σ values mean more influence of water content upon measurement element concentration. The obtained recovery rates allowed a qualitative determination. The concentration for the most elements reduced linearly with increasing water content. A predictable behavior of the water content on pXRF results as function of atomic number was not found. Elements identified by Lα spectral line with highest Z were more impacted by water content than elements identified by Kα line with lowest Z. Ti, Cr and Fe was not significantly influenced by water content, and Sr was the most impacted. Our findings contribute to decision-making before characterization earth materials via pXRF, obliging the use of dry samples for determination of impacted elements or by using moisture-corrected data.
URI: http://repositorio.ufla.br/jspui/handle/1/40806
Aparece nas coleções:DCS - Artigos publicados em periódicos



Este item está licenciada sob uma Licença Creative Commons Creative Commons