Please use this identifier to cite or link to this item: http://repositorio.ufla.br/jspui/handle/1/38791
Full metadata record
DC FieldValueLanguage
dc.creatorAlcântara, Lizzy Ayra Pereira-
dc.creatorMinim, Luis Antonio-
dc.creatorMinim, Valéria Paula Rodrigues-
dc.creatorBonomo, Renata Cristina Ferreira-
dc.creatorSilva, Luis Henrique Mendes da-
dc.creatorSilva, Maria do Carmo Hespanhol da-
dc.date.accessioned2020-01-31T17:50:31Z-
dc.date.available2020-01-31T17:50:31Z-
dc.date.issued2011-07-
dc.identifier.citationALCÂNTARA, L. A. P. et al. Application of the response surface methodology for optimization of whey protein partitioning in PEG/phosphate aqueous two-phase system. Journal of Chromatography B, [S.l.], v. 879, n. 21, p. 1881-1885, July 2011.pt_BR
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S1570023211003126?via%3Dihubpt_BR
dc.identifier.urihttp://repositorio.ufla.br/jspui/handle/1/38791-
dc.description.abstractIn order to develop a new strategy for β-lactoglobulin (β-lg) removal from whey protein, partitioning of α-lactalbumin (α-la), β-lg and glycomacropeptide (Gmp) was studied using aqueous two phase systems (ATPS). A system composed of 13% (w/w) polyethylene glycol (PEG, average molar mass 2000 g/mol) and 13% (w/w) potassium phosphate was used at 25 °C. A central composite rotatable design (CCRD) associated to the response surface methodology (RSM) was applied to investigate the effects of NaCl concentration and pH on the partition of these proteins. It was found that α-la and Gmp partitioned to the top phase rich in PEG, whereas β-lg partitioned to the bottom phase rich in salt. According to the RSM, optimal conditions for β-lg removal where found where pH was equal to 6.7 and salt concentration was 0.35 mol/L. Under these conditions, the partition coefficient Kα was 0.48 and KGmp was 0.92. On the other hand, the partition coefficient Kβ was only 0.01. In such conditions β-lg preferentially concentrates in the bottom phase, while the top phase exclusively contains the proteins α-la and Gmp. Fractionation of the proteins from fresh whey was performed in a three stage cross-flow extraction system. The extraction yield for β-lg in the bottom phase was 97.3%, while the yields for α-la and Gmp in the top phase were 81.1% and 97.8%, respectively.pt_BR
dc.languageen_USpt_BR
dc.publisherElsevierpt_BR
dc.rightsrestrictAccesspt_BR
dc.sourceJournal of Chromatography Bpt_BR
dc.subjectAqueous two phase systemspt_BR
dc.subjectα-Lactalbuminpt_BR
dc.subjectβ-Lactoglobulinpt_BR
dc.subjectGlycomacropeptidept_BR
dc.titleApplication of the response surface methodology for optimization of whey protein partitioning in PEG/phosphate aqueous two-phase systempt_BR
dc.typeArtigopt_BR
Appears in Collections:DCA - Artigos publicados em periódicos

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.