Use este identificador para citar ou linkar para este item:
http://repositorio.ufla.br/jspui/handle/1/36573
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Fernandes, Jessica Colnaghi | - |
dc.creator | Nascimento, Raphael Aparecido Sanches | - |
dc.creator | Mulato, Marcelo | - |
dc.date.accessioned | 2019-09-04T10:55:44Z | - |
dc.date.available | 2019-09-04T10:55:44Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | FERNANDES, J. C.; NASCIMENTO, R. A. S.; MULATO, M. Effects of measurements conditions on an extended-gate FET used as pH sensor. Materials Research, São Carlos, v. 19, n. 1, Jan./Feb. 2016. | pt_BR |
dc.identifier.uri | http://repositorio.ufla.br/jspui/handle/1/36573 | - |
dc.description.abstract | Fluorine-doped tin oxide (SnO2:F) was investigate as the sensitive part of a pH sensor in the extended-gate field effect transistors (EGFET) device, which provided a linear response for pH range from 2 to 12; the sensitivity was 37 mV.pH-1 for experiments performed in absence of light. Neutral pH, leads to a transistor’s electric current remained practically constant, suggesting that pH 7 correspond to the isoelectric point of the SnO2:F samples. For acid and alkaline pH, the power law varied along time and stabilized at about 10 min. UV-vis light did not alter the results. The transistor’s electric current increased with the operating temperature increases. Once that small change in the operating conditions can alter the results, the physical mechanisms underlying the sensing process must be clearly understood. It is essential to monitor transient response and measurements conditions. | pt_BR |
dc.language | en_US | pt_BR |
dc.rights | Attribution 4.0 International | * |
dc.rights | acesso aberto | pt_BR |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
dc.source | Materials Research | pt_BR |
dc.subject | Extended-gate FET | pt_BR |
dc.subject | Fluorine-doped tin oxide | pt_BR |
dc.subject | pH sensor | pt_BR |
dc.subject | Temperature dependence | pt_BR |
dc.subject | Time evolution | pt_BR |
dc.title | Effects of measurements conditions on an extended-gate FET used as pH sensor | pt_BR |
dc.type | Artigo | pt_BR |
Aparece nas coleções: | DFI - Artigos publicados em periódicos |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
ARTIGO_Effects of measurements conditions on an extended-gate FET used as pH sensor.pdf | 1,17 MB | Adobe PDF | Visualizar/Abrir |
Este item está licenciada sob uma Licença Creative Commons