dc.description.abstractThe results of tests with a sodium chloride tracer in a shallow maturation pond in Brazil are presented. The pond – a full-scale effluent treatment unit for around 250 p.e – was 0.80 m deep with a length/width ratio of 4.3:1, and had accumulated sludge for 12 years to about 40% of the total volume. The pond is subject to daily cycles of thermal stratification/destratification, as shown by vertical profiles of temperature, dissolved oxygen, pH and redox potential, and by Computational Fluid Dynamics simulations. Four tracer tests were undertaken. There was a tendency to complete mixing with high dispersion, and daily vertical cycles were evident in all tracer response curves, a distinctive feature of these studies. However, the reliability of the hydraulic retention time calculation, and the short-circuit and mixing indicators, is doubtful, primarily because of the liquor's high density. The study's results enabled practical consideration of the use of saline tracers in pond systems. Sodium chloride acquisition and semi-continuous sensor measurements of effluent concentrations (electrical conductivity) are both easy, but the large amount of salt required (around 300 kg for a 125 m3 pond) and solution density are limiting factors, and can yield unrepresentative results, making this tracer potentially impractical, especially for larger ponds. However, the diurnal cycles of effluent tracer concentration were important in this study and assisted in verification of hydraulic behavior in the liquid column, associated with the stratification and mixing patterns.pt_BR
dc.languageen_USpt_BR
dc.publisherIWA Publishingpt_BR
dc.rightsrestrictAccesspt_BR
dc.sourceWater Practice & Tecnhologypt_BR
dc.subjectHydrodynamic characterizationpt_BR
dc.subjectPolishing pondspt_BR
dc.subjectSaline tracerpt_BR
dc.subjectTracer testspt_BR
dc.subjectCaracterização hidrodinâmicapt_BR
dc.subjectLagoas de polimentopt_BR
dc.subjectTraçador salinopt_BR
dc.subjectTestes de rastreamentopt_BR
dc.titleSodium chloride as a tracer for hydrodynamic characterization of a shallow maturation pondpt_BR
dc.typeArtigopt_BR
Appears in Collections:DRH - Artigos publicados em periódicos

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.