Use este identificador para citar ou linkar para este item:
http://repositorio.ufla.br/jspui/handle/1/30256
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Souza, Ana Paula Ruas de | - |
dc.creator | Felix, Fabiana Silva | - |
dc.creator | Castro, Pollyana Souza | - |
dc.creator | Angnes, Lucio | - |
dc.creator | Bertotti, Mauro | - |
dc.date.accessioned | 2018-08-30T13:28:27Z | - |
dc.date.available | 2018-08-30T13:28:27Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | SOUZA, A. P. R. de et al. Gold random microarrays: design, characterization and amperometric determination of ciclopirox olamine in pharmaceutical products. Analytical Methods, [S. l.], v. 8, n. 54, p. 1078-1083, 2016. | pt_BR |
dc.identifier.uri | http://pubs.rsc.org/en/content/articlelanding/2016/ay/c5ay03157e#!divAbstract | pt_BR |
dc.identifier.uri | http://repositorio.ufla.br/jspui/handle/1/30256 | - |
dc.description.abstract | In this work, a disposable gold random microarray (GRM) sensor was developed and applied for the determination of ciclopirox olamine in 0.10 mol L−1 Britton Robinson buffer (pH 5.0). The GRM was fabricated by the deposition of two toner pattern masks, the first mask delimiting the disc area and the second one (with 90% of toner) defining the microarrays. Following the optimization of the experimental parameters, the proposed sensor presented excellent analytical properties for the amperometric detection of ciclopirox olamine at +0.85 V vs. Ag/AgCl(KClsat). The usefulness of the GRM sensor was confirmed by determining ciclopirox olamine in commercial products. The results obtained were in good agreement with those found by potentiometric titration and the labelled values. The proposed GRM platform can be produced with high throughput and is cost-effective and disposable, hence no pre-treatment is required between measurements. | pt_BR |
dc.language | en_US | pt_BR |
dc.publisher | Royal Society of Chemistry | pt_BR |
dc.rights | restrictAccess | pt_BR |
dc.source | Analytical Methods | pt_BR |
dc.subject | Gold random microarray | pt_BR |
dc.subject | Ciclopirox olamine | pt_BR |
dc.subject | Microarranjo aleatório dourado | pt_BR |
dc.title | Gold random microarrays: design, characterization and amperometric determination of ciclopirox olamine in pharmaceutical products | pt_BR |
dc.type | Artigo | pt_BR |
Aparece nas coleções: | DQI - Artigos publicados em periódicos |
Arquivos associados a este item:
Não existem arquivos associados a este item.
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.